Diesel-Pro

Your Best Buy in Diesel Generators

Home
Generators
Construction Related Equi
Trailering Accessories
Ag Equipment
Site Map
Contact Us
Generator Operating Instr
Generator Parts
 
2.0 Hp 1250 Watt GAS Generator
 
 
This is the choke lever for  a 1250 watt generator shown in the OFF position.
To choke slide the lever to the left. Note: Right above choke is the ON/OFF Switch
Engine switch I is on and O is off.  This unit requires mixed gas at a ratio of 50 to 1
 
Fuel Shut Off Valve shown in the above picture is in the OFF position.
Note: This is a 1250 watt 2 horse power 2 stroke generator.
 
 
6.5 Hp 4000 Watt 4 Stroke Gas Generator
 
 
Shown is the oil fill cap, please use 5w30 SAE approved oil.
 
 
The choke lever is located right above the air filter assembly
When the choke lever is in the left position the machine is fully choked.
Fuel lever is shown in the OFF postition.
 
 
 
13Hp 8000 Watt Gas Generator
 
 
 
Picture shows the oil fill cap, please use 5w30 Sae approved oil.
Note: Slightly below and to the left is the oil drain plug.
 
 
The above picture shows the fuel valve in the OFF position.
 
 
Above picture shows choke lever location on a 13Hp 8000Watt generator.
Note: When lever is pulled out choke is ON.
 
 
 
DIESEL GENERATORS
 
LDE 6800
 
 
This is a 418cc single cylinder air cooled, direct injection diesel generator. The fuel capacity for this unit is 4.2 gallons and the oil capacity is 1.75 quarts.  Please use 15w40 SAE approved oil.
 
 
To aid in engine start up:
1. Fill unit with premium diesel fuel
2. Add engine oil
3. Remove fuel line from injector pump, while fuel is coming out of the hose reattach it to the pump.
4 Use caution when hooking up battery cable so as not to damage in-line fuse located near the starter. Any pulling on the cables will result in damage which will cause the generator to NOT start.
Warning: DO NOT USE ANY TYPE OF STARTER FLUID AT ANY TIME!!!!!!!
 
In the above picture the fuel valve lever is in the ON position.
 
 
 
The above picture shows the oil fill cap. (unit holds 1.75 quarts SAE 15w40)
 
 
 
The above picture shows the location of the engines oil filter.
It is recommended that the engine oil be changed after the first 20 hours and every 150 hours thereafter.
 
 
 
The above picture shows the engine speed switch.  It is shown in the OFF position.  Upon engine start-up move lever to the right until you feel it lock in the run position. This engine is designed to run from 3000 to 3600 RPM. Overloading or over revving the engine will result in engine damage.